Uniform Building Code, Volume 6International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 18
Page 25
... thickness of wood shingles or shakes between wood nailing boards shall be not less than three - eighths inch ... thickness set forth in Table No. 24 - I , except that the height may be increased if the thickness is increased in ...
... thickness of wood shingles or shakes between wood nailing boards shall be not less than three - eighths inch ... thickness set forth in Table No. 24 - I , except that the height may be increased if the thickness is increased in ...
Page 27
... thickness ( excluding cavity ) , height , and mortar requirements for cavity walls . [ Sec . 2412 ( b ) 2. ] Corbeling Corbels may be built only into solid masonry walls twelve inches ( 12 " ) or more in thickness . The projection for ...
... thickness ( excluding cavity ) , height , and mortar requirements for cavity walls . [ Sec . 2412 ( b ) 2. ] Corbeling Corbels may be built only into solid masonry walls twelve inches ( 12 " ) or more in thickness . The projection for ...
Page 38
International Conference of Building Officials. PLASTER BASE TABLE NO 47 - D - THICKNESS OF PLASTER ' FINISHED THICKNESS OF PLASTER FROM FACE OF LATH , MASONRY , CONCRETE Gypsum Plaster ' For Fire - resistive Construction , see Tables No ...
International Conference of Building Officials. PLASTER BASE TABLE NO 47 - D - THICKNESS OF PLASTER ' FINISHED THICKNESS OF PLASTER FROM FACE OF LATH , MASONRY , CONCRETE Gypsum Plaster ' For Fire - resistive Construction , see Tables No ...
Other editions - View all
Common terms and phrases
11 gauge anchored applied approved Basecoat BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling concrete concrete masonry units Corbeling corrosion-resistant Direction 16 Douglas Fir exceed Expanded Metal Lath exterior walls Fasteners finish coat Fire-resistive Construction firebrick FIRESTOP five-eighths FLASHING FOUNDATION four inches FROST LINE GRADE GROUP II GROUP GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster LINTEL MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum modulus of elasticity mortar nails one-fourth inch one-half inch partitions plastered ceiling-not PLATE portland cement plaster pounds per square second coat sheathing six inches SOLID MASONRY square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table thickness three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction weatherboarding width wire lath wood frame wood shingles