Page 18
... width of opening is such that more than one piece of lumber is necessary , there shall be two thicknesses of one- inch ( 1 " ) material with joints broken . ( Sec . 2508. ) WEATHER PROTECTION Asphalt - saturated felt free from holes and ...
... width of opening is such that more than one piece of lumber is necessary , there shall be two thicknesses of one- inch ( 1 " ) material with joints broken . ( Sec . 2508. ) WEATHER PROTECTION Asphalt - saturated felt free from holes and ...
Page 26
... width is less than three times its thick- ness shall be designed and constructed as required for col- umns if such pier is a structural member . [ Sec . 2417 ( c ) . ] Openings The masonry above openings shall be supported by well ...
... width is less than three times its thick- ness shall be designed and constructed as required for col- umns if such pier is a structural member . [ Sec . 2417 ( c ) . ] Openings The masonry above openings shall be supported by well ...
Page 29
... widths up to three and one - half inches ( 31⁄2 " ) net in width . Where the cavity exceeds three and one - half inches ( 31⁄2 " ) net in width , there shall be one metal tie for not more than each three square feet ( 3 sq . ft . ) of ...
... widths up to three and one - half inches ( 31⁄2 " ) net in width . Where the cavity exceeds three and one - half inches ( 31⁄2 " ) net in width , there shall be one metal tie for not more than each three square feet ( 3 sq . ft . ) of ...
Other editions - View all
Common terms and phrases
11 gauge anchored applied approved Basecoat BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling concrete concrete masonry units Corbeling corrosion-resistant Direction 16 Douglas Fir exceed Expanded Metal Lath exterior walls Fasteners finish coat Fire-resistive Construction firebrick FIRESTOP five-eighths FLASHING FOUNDATION four inches FROST LINE GRADE GROUP III GROUP GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster LINTEL MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum modulus of elasticity mortar nails one-fourth inch one-half inch partitions plastered ceiling-not PLATE portland cement plaster pounds per square second coat sheathing six inches SOLID MASONRY square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table thickness three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction weatherboarding width wire lath wood frame wood shingles