EXCEPTION : Where the entire attic is equipped with an approved automatic
sprinkler system , the attic space may be divided into areas not to exceed 9000
square feet . ( c ) Ventilation . Where determined necessary by the building
official ...
EXCEPTION : Where the entire attic is equipped with an approved automatic
sprinkler system , the attic space may be divided into areas not to exceed 9000
square feet . ( c ) Ventilation . Where determined necessary by the building
official ...
Page 638
EXCEPTION : Skylights which pass the Class “ B ” burning - brand test specified
in U . B . C . Standard No . 32 - 7 . 3 . The edges of the plastic lights or dome shall
be protected by metal or other noncombustible materials . 4 . Each skylight unit ...
EXCEPTION : Skylights which pass the Class “ B ” burning - brand test specified
in U . B . C . Standard No . 32 - 7 . 3 . The edges of the plastic lights or dome shall
be protected by metal or other noncombustible materials . 4 . Each skylight unit ...
Page 680
EXCEPTION : A noncombustible membrane structure used exclusively as a roof
and located more than 25 feet above any floor , balcony or gallery is deemed to
comply with the roof construction requirements for Type I and Type II fire ...
EXCEPTION : A noncombustible membrane structure used exclusively as a roof
and located more than 25 feet above any floor , balcony or gallery is deemed to
comply with the roof construction requirements for Type I and Type II fire ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield