Uniform Building Code |
From inside the book
Results 1-3 of 86
Page 8
Requirements for Group B Occupancies SEC . 701 . Group B Occupancies
Defined . . . . . . 702 . Construction , Height and Allowable Area . 703 . Location on
Property . . . . . . . . . . 704 . Exit Facilities . . . . . . 705 . Light , Ventilation and
Sanitation .
Requirements for Group B Occupancies SEC . 701 . Group B Occupancies
Defined . . . . . . 702 . Construction , Height and Allowable Area . 703 . Location on
Property . . . . . . . . . . 704 . Exit Facilities . . . . . . 705 . Light , Ventilation and
Sanitation .
Page 61
Chapter 6 REQUIREMENTS FOR GROUP A OCCUPANCIES Group A
Occupancies Defined Sec . 601 . Group A Occupancies shall be : Division 1 . Any
assembly building with a stage and an occupant load of 1000 or more in the
building .
Chapter 6 REQUIREMENTS FOR GROUP A OCCUPANCIES Group A
Occupancies Defined Sec . 601 . Group A Occupancies shall be : Division 1 . Any
assembly building with a stage and an occupant load of 1000 or more in the
building .
Page 65
Chapter 7 REQUIREMENTS FOR GROUP B OCCUPANCIES Group B
Occupancies Defined Sec . 701 . Group B Occupancies shall be : Division 1 .
Gasoline service stations , storage garages where no repair work is done except
exchange of ...
Chapter 7 REQUIREMENTS FOR GROUP B OCCUPANCIES Group B
Occupancies Defined Sec . 701 . Group B Occupancies shall be : Division 1 .
Gasoline service stations , storage garages where no repair work is done except
exchange of ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield