... allowable unit stress for extreme fiber in bending . b F ' . = allowable unit stress for extreme fiber in bending , adjusted for b fo slenderness . = actual unit stress for extreme fiber in bending . F = allowable unit stress in ...
... allowable unit stress for extreme fiber in bending . b F ' . = allowable unit stress for extreme fiber in bending , adjusted for b fo slenderness . = actual unit stress for extreme fiber in bending . F = allowable unit stress in ...
Page 264
... Allowable stresses for dry conditions of use shall be applicable when the moisture content in service is 16 percent ... allowable stress for compression perpendicular to grain is as follows : L1 - C , 410 psi ; L2 - D , 450 psi ...
... Allowable stresses for dry conditions of use shall be applicable when the moisture content in service is 16 percent ... allowable stress for compression perpendicular to grain is as follows : L1 - C , 410 psi ; L2 - D , 450 psi ...
Page 474
... Allowable Loads . The allowable loads based upon soil conditions shall be established in accordance with Section 2908 . EXCEPTION : Any uncased cast - in - place pile may be assumed to develop a frictional resistance equal to one ...
... Allowable Loads . The allowable loads based upon soil conditions shall be established in accordance with Section 2908 . EXCEPTION : Any uncased cast - in - place pile may be assumed to develop a frictional resistance equal to one ...
Contents
Effective Use of the Uniform Building Code | 18 |
CHAPTER | 24 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
86 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts building official ceiling column compression compression members compressive strength concrete conform dead load diameter diaphragms exceed exit exterior walls EXTREME FIBER fire fire-resistive rating flange flexural floor foot Formula framing gauge girders grade Group grout gypsum height installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panels Parallel to Grain partitions percent permitted perpendicular plaster plastic plywood portland cement pounds per square prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile stress tension tests thickness timber tion Type U.B.C. Standard values vertical welds width wire wood yield strength