Page 333
( i ) Limiting Dimensions for Compression Members . 1 . Isolated compression
member with multiple spirals . If two or more interlocking spirals are used in a
compression member , the outer boundary of the compression member shall be
taken ...
( i ) Limiting Dimensions for Compression Members . 1 . Isolated compression
member with multiple spirals . If two or more interlocking spirals are used in a
compression member , the outer boundary of the compression member shall be
taken ...
Page 334
The design of compression members shall be based on forces and moments
determined from an analysis of the structure . Such an analysis shall take into
account the influence of axial loads and variable moment of inertia on member
stiffness ...
The design of compression members shall be based on forces and moments
determined from an analysis of the structure . Such an analysis shall take into
account the influence of axial loads and variable moment of inertia on member
stiffness ...
Page 419
240 dent on the bending stiffness of rigidly connected beams and columns , the
effective length Kl of compression members shall be determined by a rational
method and shall not be less than the actual unbraced length . ( d ) Maximum
Ratios ...
240 dent on the bending stiffness of rigidly connected beams and columns , the
effective length Kl of compression members shall be determined by a rational
method and shall not be less than the actual unbraced length . ( d ) Maximum
Ratios ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield