Uniform Building Code |
From inside the book
Results 1-3 of 74
Page 135
Connections to permit movement in the plane of the panel for story drift shall be
properly designed sliding connections using slotted or oversized holes or may be
connections which permit movement by bending of steel or other connections ...
Connections to permit movement in the plane of the panel for story drift shall be
properly designed sliding connections using slotted or oversized holes or may be
connections which permit movement by bending of steel or other connections ...
Page 433
Connections Sec . 2712 . ( a ) Minimum Connections . Connections shall be
designed for all tributary forces and shall be capable of supporting not less than
six kips . · EXCEPTION : Lacing , sag bars and girts may be designed only for
tributary ...
Connections Sec . 2712 . ( a ) Minimum Connections . Connections shall be
designed for all tributary forces and shall be capable of supporting not less than
six kips . · EXCEPTION : Lacing , sag bars and girts may be designed only for
tributary ...
Page 434
27 - 3 , disposition of fillet welds to balance the forces about the neutral axis or
axes for end connections of single angle , double angle and similar - type
members is not required . Eccentricity between the gravity axes of such members
and the ...
27 - 3 , disposition of fillet welds to balance the forces about the neutral axis or
axes for end connections of single angle , double angle and similar - type
members is not required . Eccentricity between the gravity axes of such members
and the ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield