23 - 1 - HORIZONTAL FORCE FACTOR C . FOR ELEMENTS OF STRUCTURES
AND NONSTRUCTURAL COMPONENTS DIRECTION OF HORIZONTAL FORCE
PART OR PORTION OF BUILDINGS VALUE OF CO 0 . 36 1 . Exterior bearing ...
23 - 1 - HORIZONTAL FORCE FACTOR C . FOR ELEMENTS OF STRUCTURES
AND NONSTRUCTURAL COMPONENTS DIRECTION OF HORIZONTAL FORCE
PART OR PORTION OF BUILDINGS VALUE OF CO 0 . 36 1 . Exterior bearing ...
Page 175
The slenderness ratio of a column shall be the greater value obtained by dividing
the effective height h in any direction by the effective thickness t in the
corresponding direction and shall not exceed the value computed by 35 ( 4 - es .
The slenderness ratio of a column shall be the greater value obtained by dividing
the effective height h in any direction by the effective thickness t in the
corresponding direction and shall not exceed the value computed by 35 ( 4 - es .
Page 625
... FRAMING TO DIRECTION OF Center ) SURFACE FRAMING MEMBERS ( In
Inches ) Horizontal | Either Direction 16 Horizontal Perpendicular 24 Vertical
Either Direction Horizontal | Either Direction 16 Horizontal | Perpendicular | 24
Vertical ...
... FRAMING TO DIRECTION OF Center ) SURFACE FRAMING MEMBERS ( In
Inches ) Horizontal | Either Direction 16 Horizontal Perpendicular 24 Vertical
Either Direction Horizontal | Either Direction 16 Horizontal | Perpendicular | 24
Vertical ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield