Page 131
Total shear in any horizontal plane shall be distributed to the various elements of
the lateral force - resisting system in proportion to their rigidities considering the
rigidity of the horizontal bracing system or diaphragm . Rigid elements that are ...
Total shear in any horizontal plane shall be distributed to the various elements of
the lateral force - resisting system in proportion to their rigidities considering the
rigidity of the horizontal bracing system or diaphragm . Rigid elements that are ...
Page 134
Wer = the weight of the diaphragm and the elements tributary thereto at level x ,
including 25 percent of the floor live load in storage and warehouse occupancies
. The force Fps determined from Formula ( 12 - 9 ) need not exceed 0 . 30Z / Wor
...
Wer = the weight of the diaphragm and the elements tributary thereto at level x ,
including 25 percent of the floor live load in storage and warehouse occupancies
. The force Fps determined from Formula ( 12 - 9 ) need not exceed 0 . 30Z / Wor
...
Page 419
( a ) Unstiffened Elements Under Compression . Unstiffened ( projecting )
compression elements are those having one free edge parallel to the direction of
compression stress . The width of unstiffened plates shall be taken from the free
edge to ...
( a ) Unstiffened Elements Under Compression . Unstiffened ( projecting )
compression elements are those having one free edge parallel to the direction of
compression stress . The width of unstiffened plates shall be taken from the free
edge to ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield