Where the occupancy separation is horizontal , structural members supporting
the separation shall be protected by equivalent fire - resistive construction . ( c )
Types of Occupancy Separations . Occupancy separations shall be classed as ...
Where the occupancy separation is horizontal , structural members supporting
the separation shall be protected by equivalent fire - resistive construction . ( c )
Types of Occupancy Separations . Occupancy separations shall be classed as ...
Page 559
agency during fabrication and assembly . ( d ) Fire - resistive Tests . The fire -
protection rating of all types of required fire assemblies shall be determined in
accordance with the requirements specified in U . B . C . Standards No . 43 - 2
and No ...
agency during fabrication and assembly . ( d ) Fire - resistive Tests . The fire -
protection rating of all types of required fire assemblies shall be determined in
accordance with the requirements specified in U . B . C . Standards No . 43 - 2
and No ...
Page 560
( i ) Fire Dampers . Except where fire tests have shown that fire dampers are not
necessary to maintain the required fire resistance of the construction , fire
dampers complying with the requirements of U . B . C . Standard No . 43 - 7 shall
be ...
( i ) Fire Dampers . Except where fire tests have shown that fire dampers are not
necessary to maintain the required fire resistance of the construction , fire
dampers complying with the requirements of U . B . C . Standard No . 43 - 7 shall
be ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield