Page 554
... rating indicated . Any material or assembly of materials of construction tested in accordance with the re- quirements set forth in U.B.C. Standard No. 43-1 shall be rated for fire ... Fire-resistive Standards General Fire-resistive Materials.
... rating indicated . Any material or assembly of materials of construction tested in accordance with the re- quirements set forth in U.B.C. Standard No. 43-1 shall be rated for fire ... Fire-resistive Standards General Fire-resistive Materials.
Page 557
... fire- resistive thickness of such wall . ( c ) Exterior Walls . In fire - resistive exterior wall construction the fire- resistive rating shall be maintained for such walls passing through attic areas . ( d ) Nonsymmetrical Wall ...
... fire- resistive thickness of such wall . ( c ) Exterior Walls . In fire - resistive exterior wall construction the fire- resistive rating shall be maintained for such walls passing through attic areas . ( d ) Nonsymmetrical Wall ...
Page 559
... resistive Tests . The fire - protection rating of all types of re- quired fire assemblies shall be determined in accordance with the re- quirements specified in U.B.C. Standards No. 43-2 and No. 43-4 . ( e ) Hardware . Every fire ...
... resistive Tests . The fire - protection rating of all types of re- quired fire assemblies shall be determined in accordance with the re- quirements specified in U.B.C. Standards No. 43-2 and No. 43-4 . ( e ) Hardware . Every fire ...
Contents
Effective Use of the Uniform Building Code | 18 |
CHAPTER | 24 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
86 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts building official ceiling column compression compression members compressive strength concrete conform dead load diameter diaphragms exceed exit exterior walls EXTREME FIBER fire fire-resistive rating flange flexural floor foot Formula framing gauge girders grade Group grout gypsum height installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panels Parallel to Grain partitions percent permitted perpendicular plaster plastic plywood portland cement pounds per square prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile stress tension tests thickness timber tion Type U.B.C. Standard values vertical welds width wire wood yield strength