... grout shall be composed of one part portland cement to which may be added not more than one - tenth part hydrated ... grout in fireplaces and their chimneys . Coarse grout may be used in grout spaces in brick masonry 2 inches or more in ...
... grout shall be composed of one part portland cement to which may be added not more than one - tenth part hydrated ... grout in fireplaces and their chimneys . Coarse grout may be used in grout spaces in brick masonry 2 inches or more in ...
Page 159
... grout space . The cleanouts shall be sealed after inspection and before grouting . 4. The grout space ( longitudinal vertical joint ) shall be not less than 3 inches in width and not less than the thickness required by the placement of ...
... grout space . The cleanouts shall be sealed after inspection and before grouting . 4. The grout space ( longitudinal vertical joint ) shall be not less than 3 inches in width and not less than the thickness required by the placement of ...
Page 160
... grout and in which reinforcement is embedded . Requirements for construction shall be as follows : 1. All units shall be laid with full mortar beds on the face shells . All head joints shall be filled solidly with mortar for a distance ...
... grout and in which reinforcement is embedded . Requirements for construction shall be as follows : 1. All units shall be laid with full mortar beds on the face shells . All head joints shall be filled solidly with mortar for a distance ...
Contents
Effective Use of the Uniform Building Code | 18 |
CHAPTER | 24 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
86 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts building official ceiling column compression compression members compressive strength concrete conform dead load diameter diaphragms exceed exit exterior walls EXTREME FIBER fire fire-resistive rating flange flexural floor foot Formula framing gauge girders grade Group grout gypsum height installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panels Parallel to Grain partitions percent permitted perpendicular plaster plastic plywood portland cement pounds per square prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile stress tension tests thickness timber tion Type U.B.C. Standard values vertical welds width wire wood yield strength