Uniform Building Code |
From inside the book
Results 1-3 of 90
Page 127
In this system the required lateral forces are resisted by shear walls or braced
frames as hereinafter defined . BRACED FRAME is a truss system or its
equivalent which is provided to resist lateral forces in the frame system and in
which the ...
In this system the required lateral forces are resisted by shear walls or braced
frames as hereinafter defined . BRACED FRAME is a truss system or its
equivalent which is provided to resist lateral forces in the frame system and in
which the ...
Page 314
All bars for tied columns shall be enclosed by lateral ties at least No . 3 in
diameter for longitudinal bars smaller than No . 11 bars and at least No . 4 in
diameter ties shall be provided for No . 11 or larger bars or bundled longitudinal
bars .
All bars for tied columns shall be enclosed by lateral ties at least No . 3 in
diameter for longitudinal bars smaller than No . 11 bars and at least No . 4 in
diameter ties shall be provided for No . 11 or larger bars or bundled longitudinal
bars .
Page 478
B - ALLOWABLE FOUNDATION AND LATERAL PRESSURE LATERAL
BEARING ALLOW . LBS . / SQ . ABLE FT . / FT . OF LATERAL SLIDING '
FOUNDA . DEPTH RESIS TION BELOW TANCE PRESSURE NATURAL COEFFI
: LBS . / SQ .
B - ALLOWABLE FOUNDATION AND LATERAL PRESSURE LATERAL
BEARING ALLOW . LBS . / SQ . ABLE FT . / FT . OF LATERAL SLIDING '
FOUNDA . DEPTH RESIS TION BELOW TANCE PRESSURE NATURAL COEFFI
: LBS . / SQ .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield