Uniform Building Code |
From inside the book
Results 1-3 of 83
Page 149
... least Grade MW . Where severe frost action occurs in the presence of moisture , brick shall be at least Grade SW . ( d ) Concrete Brick . Building brick of concrete shall be of a quality at least equal to the requirements set forth in ...
... least Grade MW . Where severe frost action occurs in the presence of moisture , brick shall be at least Grade SW . ( d ) Concrete Brick . Building brick of concrete shall be of a quality at least equal to the requirements set forth in ...
Page 168
... least 180 degrees . C. Embedment above or below the mid - depth of the beam on the compression side , a distance ... least 90 degrees tightly around a longitudinal rein- forcing bar not less in diameter than the stirrup bar , and shall ...
... least 180 degrees . C. Embedment above or below the mid - depth of the beam on the compression side , a distance ... least 90 degrees tightly around a longitudinal rein- forcing bar not less in diameter than the stirrup bar , and shall ...
Page 571
... least 45 percent solid . - 6 struction ) 15 Two cells in wall thickness , units at least 40 percent solid . 8 17 Two cells in wall thickness , units at least 49 percent solid . 8 Three cells in wall thickness , units at least 40 percent ...
... least 45 percent solid . - 6 struction ) 15 Two cells in wall thickness , units at least 40 percent solid . 8 17 Two cells in wall thickness , units at least 49 percent solid . 8 Three cells in wall thickness , units at least 40 percent ...
Contents
Effective Use of the Uniform Building Code | 18 |
CHAPTER | 24 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
86 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts building official ceiling column compression compression members compressive strength concrete conform dead load diameter diaphragms exceed exit exterior walls EXTREME FIBER fire fire-resistive rating flange flexural floor foot Formula framing gauge girders grade Group grout gypsum height installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panels Parallel to Grain partitions percent permitted perpendicular plaster plastic plywood portland cement pounds per square prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile stress tension tests thickness timber tion Type U.B.C. Standard values vertical welds width wire wood yield strength