Uniform Building Code |
From inside the book
Results 1-3 of 83
Page 62
... located on the public street or on the ac- cess way . The main assembly floor of Division 1 Occupancies shall be located at or near the adjacent ground level . For fire - resistive protection of exterior walls and openings , as deter ...
... located on the public street or on the ac- cess way . The main assembly floor of Division 1 Occupancies shall be located at or near the adjacent ground level . For fire - resistive protection of exterior walls and openings , as deter ...
Page 89
... located in the corridor or area giving access to rooms used for sleeping purposes . In an efficiency dwelling unit , hotel sleeping room and in hotel suites , the detector shall be centrally located on the ceiling of the main room or ...
... located in the corridor or area giving access to rooms used for sleeping purposes . In an efficiency dwelling unit , hotel sleeping room and in hotel suites , the detector shall be centrally located on the ceiling of the main room or ...
Page 543
... located within the enclosures . Except in buildings equipped with an approved automatic sprinkler system , risers and laterals of Class I standpipe systems not located within an enclosed stairway or smokeproof enclosure shall be ...
... located within the enclosures . Except in buildings equipped with an approved automatic sprinkler system , risers and laterals of Class I standpipe systems not located within an enclosed stairway or smokeproof enclosure shall be ...
Contents
Effective Use of the Uniform Building Code | 18 |
CHAPTER | 24 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
86 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts building official ceiling column compression compression members compressive strength concrete conform dead load diameter diaphragms exceed exit exterior walls EXTREME FIBER fire fire-resistive rating flange flexural floor foot Formula framing gauge girders grade Group grout gypsum height installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panels Parallel to Grain partitions percent permitted perpendicular plaster plastic plywood portland cement pounds per square prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile stress tension tests thickness timber tion Type U.B.C. Standard values vertical welds width wire wood yield strength