Uniform Building Code |
From inside the book
Results 1-3 of 89
Page 36
... portion thereof before the same is completed , he may issue a temporary Certificate of Oc- cupancy for the use of a portion or portions of a building or structure prior to the completion of the entire building or structure . ( e ) ...
... portion thereof before the same is completed , he may issue a temporary Certificate of Oc- cupancy for the use of a portion or portions of a building or structure prior to the completion of the entire building or structure . ( e ) ...
Page 41
... portion thereof , exclusive of vent shafts and courts . The floor area of a building , or portion thereof , not provided with sur- rounding exterior walls shall be the usable area under the horizontal pro- jection of the roof or floor ...
... portion thereof , exclusive of vent shafts and courts . The floor area of a building , or portion thereof , not provided with sur- rounding exterior walls shall be the usable area under the horizontal pro- jection of the roof or floor ...
Page 498
... portion thereof shall be determined by dividing the floor area assigned to that use by the square feet per occupant as set forth in Table No. 33 - A . EXCEPTIONS : 1. The occupant load of an area having fixed seats shall be determined ...
... portion thereof shall be determined by dividing the floor area assigned to that use by the square feet per occupant as set forth in Table No. 33 - A . EXCEPTIONS : 1. The occupant load of an area having fixed seats shall be determined ...
Contents
Effective Use of the Uniform Building Code | 18 |
CHAPTER | 24 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
86 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts building official ceiling column compression compression members compressive strength concrete conform dead load diameter diaphragms exceed exit exterior walls EXTREME FIBER fire fire-resistive rating flange flexural floor foot Formula framing gauge girders grade Group grout gypsum height installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panels Parallel to Grain partitions percent permitted perpendicular plaster plastic plywood portland cement pounds per square prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile stress tension tests thickness timber tion Type U.B.C. Standard values vertical welds width wire wood yield strength