Uniform Building Code |
From inside the book
Results 1-3 of 86
Page 36
A description of that portion of the building for which the certificate is issued . 5 . A
statement that the described portion of the building complies with the
requirements of this code for the group and division of occupancy and the use for
which the ...
A description of that portion of the building for which the certificate is issued . 5 . A
statement that the described portion of the building complies with the
requirements of this code for the group and division of occupancy and the use for
which the ...
Page 41
FLOOR AREA is the area included within the surrounding exterior walls of a
building or portion thereof , exclusive of vent shafts and courts . The floor area of
a building , or portion thereof , not provided with surrounding exterior walls shall
be ...
FLOOR AREA is the area included within the surrounding exterior walls of a
building or portion thereof , exclusive of vent shafts and courts . The floor area of
a building , or portion thereof , not provided with surrounding exterior walls shall
be ...
Page 498
The occupant load permitted in any building or portion thereof shall be
determined by dividing the floor area assigned to that use by the square feet per
occupant as set forth in Table No . 33 - A . EXCEPTIONS : 1 . The occupant load
of an area ...
The occupant load permitted in any building or portion thereof shall be
determined by dividing the floor area assigned to that use by the square feet per
occupant as set forth in Table No . 33 - A . EXCEPTIONS : 1 . The occupant load
of an area ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield