24 - E - ALLOWABLE UNIT WORKING STRESS REINFORCED GYPSUM
CONCRETE CLASS A CLASS B TYPE OF STRESS FACTOR ( Pounds per sq .
Inch ) Flexural Compression . 25f 125 250 Axial Compression or Bearing . . . .
100 200 ...
24 - E - ALLOWABLE UNIT WORKING STRESS REINFORCED GYPSUM
CONCRETE CLASS A CLASS B TYPE OF STRESS FACTOR ( Pounds per sq .
Inch ) Flexural Compression . 25f 125 250 Axial Compression or Bearing . . . .
100 200 ...
Page 476
The effective prestress in the pile shall be not less than 400 pounds per square
inch for piles up to 30 feet in length , 550 pounds per square inch for piles up to
50 feet in length , and 700 pounds per square inch for piles greater than 50 feet
in ...
The effective prestress in the pile shall be not less than 400 pounds per square
inch for piles up to 30 feet in length , 550 pounds per square inch for piles up to
50 feet in length , and 700 pounds per square inch for piles greater than 50 feet
in ...
Page 619
4 pounds , No . 18 gauge , 1 " x 1 " 6 1 . 4 pounds , No . 17 gauge , 142 "
Hexagonal6 1 . 4 pounds , No . 18 gauge , 1 " Hexagonale 7 . Wire Fabric Lath
Woven : 24 24 16 619 TABLE NO . 47 - C - TYPES OF LATH. 16 | 16 16 . 8 . 38 "
Gypsum ...
4 pounds , No . 18 gauge , 1 " x 1 " 6 1 . 4 pounds , No . 17 gauge , 142 "
Hexagonal6 1 . 4 pounds , No . 18 gauge , 1 " Hexagonale 7 . Wire Fabric Lath
Woven : 24 24 16 619 TABLE NO . 47 - C - TYPES OF LATH. 16 | 16 16 . 8 . 38 "
Gypsum ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield