Uniform Building Code |
From inside the book
Results 1-3 of 92
Page 338
... reinforcement shall be spaced not farther apart than three times the wall thickness nor 18 inches . 4. Vertical reinforcement need not be provided with lateral ties if such reinforcement is 0.01 times the gross concrete area or less ...
... reinforcement shall be spaced not farther apart than three times the wall thickness nor 18 inches . 4. Vertical reinforcement need not be provided with lateral ties if such reinforcement is 0.01 times the gross concrete area or less ...
Page 373
... reinforcement shall be uniformly distributed in the outer portions of the footing . Reinforcement in band width b = 2 Total reinforcement in short direction ( B + 1 ) where ẞ is the ratio of the long side to the short side of the ...
... reinforcement shall be uniformly distributed in the outer portions of the footing . Reinforcement in band width b = 2 Total reinforcement in short direction ( B + 1 ) where ẞ is the ratio of the long side to the short side of the ...
Page 387
... reinforcement f , shall be 60,000 psi . y ( f ) Reinforcement Requirements . The area of reinforcement in square inches per foot of width of shell shall not exceed 7.2hf ' / f , nor 29,000 h / fy . If the deviation of the reinforcement ...
... reinforcement f , shall be 60,000 psi . y ( f ) Reinforcement Requirements . The area of reinforcement in square inches per foot of width of shell shall not exceed 7.2hf ' / f , nor 29,000 h / fy . If the deviation of the reinforcement ...
Contents
Effective Use of the Uniform Building Code | 18 |
CHAPTER | 24 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
86 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts building official ceiling column compression compression members compressive strength concrete conform dead load diameter diaphragms exceed exit exterior walls EXTREME FIBER fire fire-resistive rating flange flexural floor foot Formula framing gauge girders grade Group grout gypsum height installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panels Parallel to Grain partitions percent permitted perpendicular plaster plastic plywood portland cement pounds per square prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile stress tension tests thickness timber tion Type U.B.C. Standard values vertical welds width wire wood yield strength