Page 18
... engineering regulations and requirements for materials of construction . See Chapters 23 through 29 . The following is a sample form for adoption of the 18 EFFECTIVE USE OF THE UNIFORM Effective Use of the Uniform Building Code.
... engineering regulations and requirements for materials of construction . See Chapters 23 through 29 . The following is a sample form for adoption of the 18 EFFECTIVE USE OF THE UNIFORM Effective Use of the Uniform Building Code.
Page 19
International Conference of Building Officials. The following is a sample form for adoption of the Uniform Building Code and Uniform Building Code Standards . SAMPLE ORDINANCE FOR ADOPTION OF THE UNIFORM BUILDING CODE AND UNIFORM ...
International Conference of Building Officials. The following is a sample form for adoption of the Uniform Building Code and Uniform Building Code Standards . SAMPLE ORDINANCE FOR ADOPTION OF THE UNIFORM BUILDING CODE AND UNIFORM ...
Page 302
... sampling and testing shall be made in accordance with the provi- sions of this section . Samples of strength tests of ... sample tested at 28 days or the specified earlier age . 3. The strength level of the concrete will be considered ...
... sampling and testing shall be made in accordance with the provi- sions of this section . Samples of strength tests of ... sample tested at 28 days or the specified earlier age . 3. The strength level of the concrete will be considered ...
Contents
Effective Use of the Uniform Building Code | 18 |
CHAPTER | 24 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
86 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts building official ceiling column compression compression members compressive strength concrete conform dead load diameter diaphragms exceed exit exterior walls EXTREME FIBER fire fire-resistive rating flange flexural floor foot Formula framing gauge girders grade Group grout gypsum height installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panels Parallel to Grain partitions percent permitted perpendicular plaster plastic plywood portland cement pounds per square prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile stress tension tests thickness timber tion Type U.B.C. Standard values vertical welds width wire wood yield strength