Uniform Building Code |
From inside the book
Results 1-3 of 90
Page 281
... SPANS FOR PLYWOOD SUBFLOOR AND ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND FACE GRAIN PERPENDICULAR TO SUPPORTS1 ' ROOF2 PANEL PLYWOOD IDENTIFICATION THICKNESS MAXIMUM SPAN LOAD ( IN POUNDS INDEX3 ( Inch ) ( In inches ) PER ...
... SPANS FOR PLYWOOD SUBFLOOR AND ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND FACE GRAIN PERPENDICULAR TO SUPPORTS1 ' ROOF2 PANEL PLYWOOD IDENTIFICATION THICKNESS MAXIMUM SPAN LOAD ( IN POUNDS INDEX3 ( Inch ) ( In inches ) PER ...
Page 319
... spans ; and B. Design dead load on all spans with full design live load on alternate spans . 3. Span length . The span length of members that are not built integrally with their supports shall be considered the clear span plus the depth ...
... spans ; and B. Design dead load on all spans with full design live load on alternate spans . 3. Span length . The span length of members that are not built integrally with their supports shall be considered the clear span plus the depth ...
Page 362
... spans within a panel not greater than 2.0 . The successive span lengths in each direction shall not differ by more than one - third of the longer span . Columns may be offset a maximum of 10 percent of the span , in direc- tion of the ...
... spans within a panel not greater than 2.0 . The successive span lengths in each direction shall not differ by more than one - third of the longer span . Columns may be offset a maximum of 10 percent of the span , in direc- tion of the ...
Contents
Effective Use of the Uniform Building Code | 18 |
CHAPTER | 24 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
86 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts building official ceiling column compression compression members compressive strength concrete conform dead load diameter diaphragms exceed exit exterior walls EXTREME FIBER fire fire-resistive rating flange flexural floor foot Formula framing gauge girders grade Group grout gypsum height installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panels Parallel to Grain partitions percent permitted perpendicular plaster plastic plywood portland cement pounds per square prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile stress tension tests thickness timber tion Type U.B.C. Standard values vertical welds width wire wood yield strength