Where required there shall be special inspection as specified in Section 306 to
insure that the construction and workmanship requirements of this subsection
and chapter are satisfied . In determining the stresses in brick masonry , the
effects of ...
Where required there shall be special inspection as specified in Section 306 to
insure that the construction and workmanship requirements of this subsection
and chapter are satisfied . In determining the stresses in brick masonry , the
effects of ...
Page 207
The framing of exterior and interior walls shall be in accordance with provisions
specified in Section 2518 unless a specific design is furnished . ( e ) Floor
Framing . Wood - joisted floors shall be framed and constructed and anchored to
...
The framing of exterior and interior walls shall be in accordance with provisions
specified in Section 2518 unless a specific design is furnished . ( e ) Floor
Framing . Wood - joisted floors shall be framed and constructed and anchored to
...
Page 393
The minimum specified 28 - day strength of the concrete f ' , shall be 3000
pounds per square inch . The maximum specified strength for lightweight
concrete shall be limited to 4000 psi . 2 . Reinforcement . All longitudinal
reinforcing steel in ...
The minimum specified 28 - day strength of the concrete f ' , shall be 3000
pounds per square inch . The maximum specified strength for lightweight
concrete shall be limited to 4000 psi . 2 . Reinforcement . All longitudinal
reinforcing steel in ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield