F . = Axial unit stress permitted by this code at ' the point under consideration , if
member were carrying axial load only , including any increase in stress allowed
by this section . fo = Computed flexural unit stress . . F = Flexural unit stress ...
F . = Axial unit stress permitted by this code at ' the point under consideration , if
member were carrying axial load only , including any increase in stress allowed
by this section . fo = Computed flexural unit stress . . F = Flexural unit stress ...
Page 188
Fy = allowable unit stress for extreme fiber in bending . = allowable unit stress for
extreme fiber in bending , adjusted for slenderness . = actual unit stress for
extreme fiber in bending . F . = allowable unit stress in compression parallel to
grain .
Fy = allowable unit stress for extreme fiber in bending . = allowable unit stress for
extreme fiber in bending , adjusted for slenderness . = actual unit stress for
extreme fiber in bending . F . = allowable unit stress in compression parallel to
grain .
Page 406
theory , to the shear yield stress of web material ; equal to 772EkV3 12 ( 1 - 02 ) (
h / t ) 2F , or 190k hlt VE [ See Section 2707 ( e ) ) . = Factor depending upon type
of transverse stiffeners . = Modulus of elasticity of steel ( 29 , 000 kips per ...
theory , to the shear yield stress of web material ; equal to 772EkV3 12 ( 1 - 02 ) (
h / t ) 2F , or 190k hlt VE [ See Section 2707 ( e ) ) . = Factor depending upon type
of transverse stiffeners . = Modulus of elasticity of steel ( 29 , 000 kips per ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield