Uniform Building Code |
From inside the book
Results 1-3 of 90
Page 88
If any room has a furred ceiling , the prescribed ceiling height is required in two -
thirds the area thereof , but in no case shall the height of the furred ceiling be less
than 7 feet . ( b ) Floor Area . Every dwelling unit shall have at least one room ...
If any room has a furred ceiling , the prescribed ceiling height is required in two -
thirds the area thereof , but in no case shall the height of the furred ceiling be less
than 7 feet . ( b ) Floor Area . Every dwelling unit shall have at least one room ...
Page 157
Hollow Unit Masonry Sec . 2411 . ( a ) General . Hollow unit masonry is that type
of construction made with hollow masonry units in which the units are all laid and
set in mortar . All units shall be laid with full face shell mortar beds . All head and
...
Hollow Unit Masonry Sec . 2411 . ( a ) General . Hollow unit masonry is that type
of construction made with hollow masonry units in which the units are all laid and
set in mortar . All units shall be laid with full face shell mortar beds . All head and
...
Page 188
Fy = allowable unit stress for extreme fiber in bending . = allowable unit stress for
extreme fiber in bending , adjusted for slenderness . = actual unit stress for
extreme fiber in bending . F . = allowable unit stress in compression parallel to
grain .
Fy = allowable unit stress for extreme fiber in bending . = allowable unit stress for
extreme fiber in bending , adjusted for slenderness . = actual unit stress for
extreme fiber in bending . F . = allowable unit stress in compression parallel to
grain .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
497 | 36 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
91 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved axial bars beam bearing bending bolts building building official Chapter column compression compressive stress computed concrete conform connections considered construction continuous cover Decking depth determined diameter direction distance Division edge effective elements equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange flexural floor foot forces Formula frame girders grade Grain greater Group height horizontal inches joints lateral least length less limited live load load located lumber masonry materials maximum Occupancies openings panel parallel percent permitted placed plate portion pounds prestressing protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab spacing span specified splices square inch steel strength stress Structural Stud surface Table taken tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood yield