International Residential Code for One- and Two-family DwellingsThe 2000 International Residential Code brings uniformity to the construction of one- and two-family dwellings and townhouses. A comprehensive code for building design, this book brings together all building, plumbing, mechanical, and fuel gas provisions. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of materials and building designs. |
From inside the book
Results 1-3 of 94
Page 67
... ( inches ) For SI : 1 inch = 25.4 mm , 1 foot = 304.8 mm , 1 pound per square inch = 6.895 Pa . a . Mortar shall be ... 12 inches ( 305 mm ) of the wall , 2. Wall height shall not exceed 8 feet ( 2438 mm ) , 3. Height of unbalanced ...
... ( inches ) For SI : 1 inch = 25.4 mm , 1 foot = 304.8 mm , 1 pound per square inch = 6.895 Pa . a . Mortar shall be ... 12 inches ( 305 mm ) of the wall , 2. Wall height shall not exceed 8 feet ( 2438 mm ) , 3. Height of unbalanced ...
Page 203
... ( inches ) APPLICATION Application without adhesive ORIENTATION OF GYPSUM BOARD TO FRAMING TABLE R702.3.5 MINIMUM ... 12 318 Wall Either direction 16 8 16 head . Ceiling Either direction 16 7 12 Ceilingd Perpendicular 24 7 12 1/2 Wall ...
... ( inches ) APPLICATION Application without adhesive ORIENTATION OF GYPSUM BOARD TO FRAMING TABLE R702.3.5 MINIMUM ... 12 318 Wall Either direction 16 8 16 head . Ceiling Either direction 16 7 12 Ceilingd Perpendicular 24 7 12 1/2 Wall ...
Page 338
... inches ( 64 415 mm2 ) . One opening shall commence within 12 inches ( 305 mm ) of the top , and one opening shall commence within 12 inches ( 305 mm ) of the bottom of the enclosure ( see Figure G2407.10 ) . The minimum dimension of air ...
... inches ( 64 415 mm2 ) . One opening shall commence within 12 inches ( 305 mm ) of the top , and one opening shall commence within 12 inches ( 305 mm ) of the bottom of the enclosure ( see Figure G2407.10 ) . The minimum dimension of air ...
Contents
AE302 Application for Permit | 3 |
E3509 Bonding | 20 |
P2605 Support | 384 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance cold-formed steel comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet Figure fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints kN/m² length less light-frame construction LINTEL listed and labeled located lumber manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles