International Residential Code for One- and Two-family DwellingsThe 2000 International Residential Code brings uniformity to the construction of one- and two-family dwellings and townhouses. A comprehensive code for building design, this book brings together all building, plumbing, mechanical, and fuel gas provisions. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of materials and building designs. |
From inside the book
Results 1-3 of 60
Page 76
... Drainage and dampproofing / waterproofing . ICF foundation basements shall be drained and damp- proofed / waterproofed in accordance with Sections R405 and R406 . SECTION R405 FOUNDATION DRAINAGE R405.1 Concrete or masonry foundations .
... Drainage and dampproofing / waterproofing . ICF foundation basements shall be drained and damp- proofed / waterproofed in accordance with Sections R405 and R406 . SECTION R405 FOUNDATION DRAINAGE R405.1 Concrete or masonry foundations .
Page 408
... drainage piping and other materials , including steel , plastic and copper may be made with a lead and oakum joint and an approved caulk- ing ferrule of the other material or by a lead and oakum joint directly with the other material ...
... drainage piping and other materials , including steel , plastic and copper may be made with a lead and oakum joint and an approved caulk- ing ferrule of the other material or by a lead and oakum joint directly with the other material ...
Page 410
... drainage lines . P3005.2.3 Underground drainage cleanouts . When installed in underground drains , cleanouts shall be extended vertically to or above finished grade either inside or outside the building . P3005.2.4 Change of direction ...
... drainage lines . P3005.2.3 Underground drainage cleanouts . When installed in underground drains , cleanouts shall be extended vertically to or above finished grade either inside or outside the building . P3005.2.4 Change of direction ...
Contents
AE302 Application for Permit | 3 |
E3509 Bonding | 20 |
P2605 Support | 384 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance cold-formed steel comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet Figure fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints kN/m² length less light-frame construction LINTEL listed and labeled located lumber manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles