International Residential Code for One- and Two-family DwellingsThe 2000 International Residential Code brings uniformity to the construction of one- and two-family dwellings and townhouses. A comprehensive code for building design, this book brings together all building, plumbing, mechanical, and fuel gas provisions. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of materials and building designs. |
From inside the book
Results 1-3 of 78
Page 414
... fixture being vented . P3104.5 Height above fixtures . A connection between a vent pipe and a vent stack or stack vent shall be made at least 6 inches ( 152 mm ) above the flood level rim of the highest fixture served by the vent ...
... fixture being vented . P3104.5 Height above fixtures . A connection between a vent pipe and a vent stack or stack vent shall be made at least 6 inches ( 152 mm ) above the flood level rim of the highest fixture served by the vent ...
Page 415
... fixture drains or downstream of the interconnection . P3107.3 Connection at different levels . Where the fixture drains connect at different levels , the vent shall connect as a vertical extension of the vertical drain . The vertical ...
... fixture drains or downstream of the interconnection . P3107.3 Connection at different levels . Where the fixture drains connect at different levels , the vent shall connect as a vertical extension of the vertical drain . The vertical ...
Page 482
... FIXTURE INSTALLATION E3904.1 Outlet box covers . In a completed installation , each outlet box shall be provided with a cover except where cov- ered by means of a fixture canopy ... FIXTURES E3904 Fixture Installation E3905 Track Lighting.
... FIXTURE INSTALLATION E3904.1 Outlet box covers . In a completed installation , each outlet box shall be provided with a cover except where cov- ered by means of a fixture canopy ... FIXTURES E3904 Fixture Installation E3905 Track Lighting.
Contents
AE302 Application for Permit | 3 |
E3509 Bonding | 20 |
P2605 Support | 384 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance cold-formed steel comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet Figure fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints kN/mē length less light-frame construction LINTEL listed and labeled located lumber manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles