International Residential Code for One- and Two-family DwellingsThe 2000 International Residential Code brings uniformity to the construction of one- and two-family dwellings and townhouses. A comprehensive code for building design, this book brings together all building, plumbing, mechanical, and fuel gas provisions. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of materials and building designs. |
From inside the book
Results 1-3 of 41
Page 261
... flue gases to the exterior safely . R1001.1.1 Support . Masonry chimneys shall be supported on foundations of solid masonry or concrete at least 12 ... Flue lining ( installation ) . Flue liners shall 2000 INTERNATIONAL RESIDENTIAL CODE® 261.
... flue gases to the exterior safely . R1001.1.1 Support . Masonry chimneys shall be supported on foundations of solid masonry or concrete at least 12 ... Flue lining ( installation ) . Flue liners shall 2000 INTERNATIONAL RESIDENTIAL CODE® 261.
Page 262
... Flue lining ( installation ) . Flue liners shall be installed in accordance with ASTM C 1283 and extend from a point not less than 8 inches ( 203 mm ) below the lowest inlet or , in the case of fireplaces , from the top of the smoke ...
... Flue lining ( installation ) . Flue liners shall be installed in accordance with ASTM C 1283 and extend from a point not less than 8 inches ( 203 mm ) below the lowest inlet or , in the case of fireplaces , from the top of the smoke ...
Page 354
... flue . Means shall be pro- vided for access to the flue for inspection and cleaning . G2424.7.2 ( 501.7.2 ) Connection to factory - built fireplace flue . An appliance shall not be connected to a flue serving a factory - built fireplace ...
... flue . Means shall be pro- vided for access to the flue for inspection and cleaning . G2424.7.2 ( 501.7.2 ) Connection to factory - built fireplace flue . An appliance shall not be connected to a flue serving a factory - built fireplace ...
Contents
AE302 Application for Permit | 3 |
E3509 Bonding | 20 |
P2605 Support | 384 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance cold-formed steel comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet Figure fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints kN/m² length less light-frame construction LINTEL listed and labeled located lumber manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles