International Residential Code for One- and Two-family DwellingsThe 2000 International Residential Code brings uniformity to the construction of one- and two-family dwellings and townhouses. A comprehensive code for building design, this book brings together all building, plumbing, mechanical, and fuel gas provisions. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of materials and building designs. |
From inside the book
Results 1-3 of 14
Page 442
... GROUNDING E3507.1 System service ground . The premises wiring sys- tem shall be grounded at the service with a grounding elec- trode conductor connected to a grounding electrode system as required by this code . Grounding electrode ...
... GROUNDING E3507.1 System service ground . The premises wiring sys- tem shall be grounded at the service with a grounding elec- trode conductor connected to a grounding electrode system as required by this code . Grounding electrode ...
Page 443
... electrode of a type specified in this section or in Section E3508.2 . The supplemental electrode shall be bonded to the grounding electrode conductor , the grounded service - entrance conductor , the grounded service raceway or any grounded ...
... electrode of a type specified in this section or in Section E3508.2 . The supplemental electrode shall be bonded to the grounding electrode conductor , the grounded service - entrance conductor , the grounded service raceway or any grounded ...
Page 444
... grounding electrode conductors . Where the service - entrance conductors are paralleled in two or more raceways or ... Grounding Electrode Conductor Connection to Grounding Electrodes E4105 Grounding 489 E4106 Equipment Installation 490.
... grounding electrode conductors . Where the service - entrance conductors are paralleled in two or more raceways or ... Grounding Electrode Conductor Connection to Grounding Electrodes E4105 Grounding 489 E4106 Equipment Installation 490.
Contents
AE302 Application for Permit | 3 |
E3509 Bonding | 20 |
P2605 Support | 384 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance cold-formed steel comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet Figure fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints kN/m² length less light-frame construction LINTEL listed and labeled located lumber manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles