International Residential Code for One- and Two-family DwellingsThe 2000 International Residential Code brings uniformity to the construction of one- and two-family dwellings and townhouses. A comprehensive code for building design, this book brings together all building, plumbing, mechanical, and fuel gas provisions. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of materials and building designs. |
From inside the book
Results 1-3 of 96
Page 63
... horizontal ( 100 - percent slope ) , the toe of the slope shall be assumed to be at the intersection of a horizontal plane drawn from the top of the foundation and a plane drawn tangent to the slope at an angle of 45 de- grees ( 0.79 ...
... horizontal ( 100 - percent slope ) , the toe of the slope shall be assumed to be at the intersection of a horizontal plane drawn from the top of the foundation and a plane drawn tangent to the slope at an angle of 45 de- grees ( 0.79 ...
Page 64
... horizontal insulation below gound . Horizontal insulation placed less than 12 inches ( 305 mm ) below the ground surface or that portion of hori- zontal insulation extending outward more than 24 inches ( 610 mm ) from the foundation ...
... horizontal insulation below gound . Horizontal insulation placed less than 12 inches ( 305 mm ) below the ground surface or that portion of hori- zontal insulation extending outward more than 24 inches ( 610 mm ) from the foundation ...
Page 253
... horizontal ( 22:12 ) to four units vertical in 12 units horizontal ( 4:12 ) , double underlayment application is required in accordance with Section R905.3.3 . R905.3.3 Underlayment . Unless otherwise noted , required underlayment shall ...
... horizontal ( 22:12 ) to four units vertical in 12 units horizontal ( 4:12 ) , double underlayment application is required in accordance with Section R905.3.3 . R905.3.3 Underlayment . Unless otherwise noted , required underlayment shall ...
Contents
AE302 Application for Permit | 3 |
E3509 Bonding | 20 |
P2605 Support | 384 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance cold-formed steel comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet Figure fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints kN/mē length less light-frame construction LINTEL listed and labeled located lumber manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles