International Residential Code for One- and Two-family DwellingsThe 2000 International Residential Code brings uniformity to the construction of one- and two-family dwellings and townhouses. A comprehensive code for building design, this book brings together all building, plumbing, mechanical, and fuel gas provisions. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of materials and building designs. |
From inside the book
Results 1-3 of 13
Page 72
... Insulating concrete form foundation walls . Insulat- ing concrete form ( ICF ) foundation walls shall be designed and constructed in accordance with the provisions of this section or in accordance with the provisions of ACI 318. When ...
... Insulating concrete form foundation walls . Insulat- ing concrete form ( ICF ) foundation walls shall be designed and constructed in accordance with the provisions of this section or in accordance with the provisions of ACI 318. When ...
Page 75
... concrete slab is provided , the unbalanced backfill height shall be measured ... insulating concrete form foundation walls for buildings not greater than 60 ... insulating concrete form wall systems . Flat ICF wall systems shall comply ...
... concrete slab is provided , the unbalanced backfill height shall be measured ... insulating concrete form foundation walls for buildings not greater than 60 ... insulating concrete form wall systems . Flat ICF wall systems shall comply ...
Page 179
... INSULATING CONCRETE FORM WALL CONSTRUCTION R611.1 General . Insulating Concrete Form walls shall be de- signed and constructed in accordance with the provisions of this section or in accordance with the provisions of ACI 318 . When ACI ...
... INSULATING CONCRETE FORM WALL CONSTRUCTION R611.1 General . Insulating Concrete Form walls shall be de- signed and constructed in accordance with the provisions of this section or in accordance with the provisions of ACI 318 . When ACI ...
Contents
AE302 Application for Permit | 3 |
E3509 Bonding | 20 |
P2605 Support | 384 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance cold-formed steel comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet Figure fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints kN/m² length less light-frame construction LINTEL listed and labeled located lumber manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles