International Residential Code for One- and Two-family DwellingsThe 2000 International Residential Code brings uniformity to the construction of one- and two-family dwellings and townhouses. A comprehensive code for building design, this book brings together all building, plumbing, mechanical, and fuel gas provisions. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of materials and building designs. |
From inside the book
Results 1-3 of 88
Page 174
... joints shall be 3/8 inch ( 9.5 mm ) thick , except that the thickness of the bed joint of the starting course placed ... joints : 1/4 inch ( 6.4 mm ) , + 3/8 inch ( 9.5 mm ) . Exception : Nonload - bearing masonry elements and masonry ...
... joints shall be 3/8 inch ( 9.5 mm ) thick , except that the thickness of the bed joint of the starting course placed ... joints : 1/4 inch ( 6.4 mm ) , + 3/8 inch ( 9.5 mm ) . Exception : Nonload - bearing masonry elements and masonry ...
Page 325
... joints , compression joints and threaded adapters Brazed , soldered and mechanical fittings threaded , welded and flanged Brazed , soldered and flared mechanical fittings NOTES Joints embedded in concrete B 306 Crosslinked polyethylene ...
... joints , compression joints and threaded adapters Brazed , soldered and mechanical fittings threaded , welded and flanged Brazed , soldered and flared mechanical fittings NOTES Joints embedded in concrete B 306 Crosslinked polyethylene ...
Page 348
... joints and fittings . The type of piping joint used shall be suitable for the pressure- temperature conditions and ... joints . Pipe joints shall be threaded , flanged or welded , and nonferrous pipe shall be permitted to also be brazed ...
... joints and fittings . The type of piping joint used shall be suitable for the pressure- temperature conditions and ... joints . Pipe joints shall be threaded , flanged or welded , and nonferrous pipe shall be permitted to also be brazed ...
Contents
AE302 Application for Permit | 3 |
E3509 Bonding | 20 |
P2605 Support | 384 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance cold-formed steel comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet Figure fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints kN/m² length less light-frame construction LINTEL listed and labeled located lumber manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles