International Residential Code for One- and Two-family DwellingsThe 2000 International Residential Code brings uniformity to the construction of one- and two-family dwellings and townhouses. A comprehensive code for building design, this book brings together all building, plumbing, mechanical, and fuel gas provisions. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of materials and building designs. |
From inside the book
Results 1-3 of 94
Page 79
... joists . Structural capaci- ties and design provisions for prefabricated wood I - joists shall be established and monitored in accordance with ASTM D 5055 . R502.2 Design and construction . Floors shall be designed and constructed in ...
... joists . Structural capaci- ties and design provisions for prefabricated wood I - joists shall be established and monitored in accordance with ASTM D 5055 . R502.2 Design and construction . Floors shall be designed and constructed in ...
Page 99
... joist spans . The clear span of cold- formed steel floor joists shall not exceed the limits set forth in Table R505.3.2 . Floor joists shall have a minimum bearing length of 1.5 inches ( 38 mm ) . When continuous joists are used the ...
... joist spans . The clear span of cold- formed steel floor joists shall not exceed the limits set forth in Table R505.3.2 . Floor joists shall have a minimum bearing length of 1.5 inches ( 38 mm ) . When continuous joists are used the ...
Page 235
... joists at intervals not exceeding 8 feet ( 2438 mm ) . R802.9 Framing of openings . Openings in roof and ceiling framing shall be framed with header and trimmer joists . When the header joist span does not exceed 4 feet ( 1219 mm ) ...
... joists at intervals not exceeding 8 feet ( 2438 mm ) . R802.9 Framing of openings . Openings in roof and ceiling framing shall be framed with header and trimmer joists . When the header joist span does not exceed 4 feet ( 1219 mm ) ...
Contents
AE302 Application for Permit | 3 |
E3509 Bonding | 20 |
P2605 Support | 384 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance cold-formed steel comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet Figure fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints kN/m² length less light-frame construction LINTEL listed and labeled located lumber manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles