International Residential Code for One- and Two-family DwellingsThe 2000 International Residential Code brings uniformity to the construction of one- and two-family dwellings and townhouses. A comprehensive code for building design, this book brings together all building, plumbing, mechanical, and fuel gas provisions. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of materials and building designs. |
From inside the book
Results 1-3 of 88
Page 118
... Located at each end and at least every 25 feet on center but not less than 16 % of braced wall line . Located at each end and at least every 25 feet on center but not less than 16 % of braced wall line for Method 3 and 25 % of braced ...
... Located at each end and at least every 25 feet on center but not less than 16 % of braced wall line . Located at each end and at least every 25 feet on center but not less than 16 % of braced wall line for Method 3 and 25 % of braced ...
Page 317
... located in accordance with Sections M1804.2.5.1 through M1804.2.5.3 . The bottom of the vent terminal and air intake shall be located not less than 12 inches ( 305 mm ) above grade . M1804.2.5.1 Input 10,000 Btu / h or less . The vent ...
... located in accordance with Sections M1804.2.5.1 through M1804.2.5.3 . The bottom of the vent terminal and air intake shall be located not less than 12 inches ( 305 mm ) above grade . M1804.2.5.1 Input 10,000 Btu / h or less . The vent ...
Page 486
... located between 5 feet and 10 feet ( 1524 mm and 3048 mm ) from the inside walls of pools and outdoor spas and hot tubs , and , where so located , shall be single and of the locking and grounding type and shall be protected by ground ...
... located between 5 feet and 10 feet ( 1524 mm and 3048 mm ) from the inside walls of pools and outdoor spas and hot tubs , and , where so located , shall be single and of the locking and grounding type and shall be protected by ground ...
Contents
AE302 Application for Permit | 3 |
E3509 Bonding | 20 |
P2605 Support | 384 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance cold-formed steel comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet Figure fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints kN/m² length less light-frame construction LINTEL listed and labeled located lumber manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles