... Table No. 10 - A or Table No. 10 - B . Every factory produced duct section and fitting shall be embossed with the name of the manufacturer and the gage and type of metal used . ( e ) Tin . Existing tin ducts may be used when comfort ...
... Table No. 10 - A or Table No. 10 - B . Every factory produced duct section and fitting shall be embossed with the name of the manufacturer and the gage and type of metal used . ( e ) Tin . Existing tin ducts may be used when comfort ...
Page 161
... Table No. 22 - D . Other systems within the range of Table No. 22 - D may be sized from that table or by means of the methods specified in Subsection ( b ) of this Sec- tion . To determine the size of each section of pipe in any system ...
... Table No. 22 - D . Other systems within the range of Table No. 22 - D may be sized from that table or by means of the methods specified in Subsection ( b ) of this Sec- tion . To determine the size of each section of pipe in any system ...
Page 203
... Table No. 5-1 - D but shall not be less than 25 feet MINIMUM DISTANCE IN FEET FROM NEAREST SIDE OF ANY PUBLIC WAY OR FROM NEAREST BUILDING OR GROUP OF BUILDINGS 11⁄2 times Table No. 5-1 - D but ... TABLES 203 1970 EDITION TABLE NO . 5-1 - C.
... Table No. 5-1 - D but shall not be less than 25 feet MINIMUM DISTANCE IN FEET FROM NEAREST SIDE OF ANY PUBLIC WAY OR FROM NEAREST BUILDING OR GROUP OF BUILDINGS 11⁄2 times Table No. 5-1 - D but ... TABLES 203 1970 EDITION TABLE NO . 5-1 - C.
Contents
Part Administrative | 9 |
CHAPTER | 15 |
Part IIDefinitions and Abbreviations | 21 |
Copyright | |
17 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit Addenda air ducts approved Asbestos-cement automatic boiler Building Official capacity Chapter chimney circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating comply compressor connected construction Continued cubic feet dampers designed diameter Dichlorodifluoromethane discharge duct system equipment evaporative cooler exceed fire fire-resistance rating flame fuel fuel-burning fusible plug gage galvanized gas vent Group 1 refrigerant horsepower incinerators inlet inspection installed iron pipe size joints less liquefied petroleum gas liquid listed located low pressure machinery room main burner metal Methyl Chloride minimum oil burners opening operating outlet permit plenum portion pounds per square pressure vessel protected psig pump refrigerant piping refrigerating system relief valve Required Required Required room or space sample Section shutoff valve side smoke detector specified square inch Standard steam steel supply tank Table temperature thickness tion Uniform Building Code vapor vent pipes ventilation venting system warm-air furnace