Uniform Building Code, Volume 2International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 40
Page 96
International Conference of Building Officials. Scope Capacity Separate Systems Elevated Duct Gas Temperatures Ducts - General , Other Than Grease Hood Ducts CHAPTER 11 - VENTILATION SYSTEMS Sec . 1101. Every ventilation system which is ...
International Conference of Building Officials. Scope Capacity Separate Systems Elevated Duct Gas Temperatures Ducts - General , Other Than Grease Hood Ducts CHAPTER 11 - VENTILATION SYSTEMS Sec . 1101. Every ventilation system which is ...
Page 97
... duct wall . Every duct or plenum which is a portion of a ventilation system used for exhausting any solid particles_shall be con- structed so as to permit thorough cleaning of the entire duct system . Any such duct or plenum , having ...
... duct wall . Every duct or plenum which is a portion of a ventilation system used for exhausting any solid particles_shall be con- structed so as to permit thorough cleaning of the entire duct system . Any such duct or plenum , having ...
Page 98
... system exposed to the outside air shall be suitably protected against corrosion . ( b ) Prevention of Grease Accumulation . Every duct ... duct shall pass Ducts 98 SECTION 1107 UNIFORM MECHANICAL CODE Ducts for Grease Hoods Only.
... system exposed to the outside air shall be suitably protected against corrosion . ( b ) Prevention of Grease Accumulation . Every duct ... duct shall pass Ducts 98 SECTION 1107 UNIFORM MECHANICAL CODE Ducts for Grease Hoods Only.
Contents
Part Administrative | 9 |
CHAPTER | 15 |
Part IIDefinitions and Abbreviations | 21 |
Copyright | |
17 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit Addenda air ducts approved Asbestos-cement automatic boiler Building Official capacity Chapter chimney circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating comply compressor connected construction Continued cubic feet dampers designed diameter Dichlorodifluoromethane discharge duct system equipment evaporative cooler exceed fire fire-resistance rating flame fuel fuel-burning fusible plug gage galvanized gas vent Group 1 refrigerant horsepower incinerators inlet inspection installed iron pipe size joints less liquefied petroleum gas liquid listed located low pressure machinery room main burner metal Methyl Chloride minimum oil burners opening operating outlet permit plenum portion pounds per square pressure vessel protected psig pump refrigerant piping refrigerating system relief valve Required Required Required room or space sample Section shutoff valve side smoke detector specified square inch Standard steam steel supply tank Table temperature thickness tion Uniform Building Code vapor vent pipes ventilation venting system warm-air furnace