Page 27
... FUSIBLE PLUG is a device arranged to relieve the pres- sure in a container by operation of a fusible member at a predetermined temperature . Sec . 409. GALVANIZED STEEL is any steel conforming G to the requirements of U.M.C. Standard No ...
... FUSIBLE PLUG is a device arranged to relieve the pres- sure in a container by operation of a fusible member at a predetermined temperature . Sec . 409. GALVANIZED STEEL is any steel conforming G to the requirements of U.M.C. Standard No ...
Page 121
... fusible plug , or rupture member , pro- vided , however , that a fusible plug is permitted only on the high pressure side of the refrigerating system . Pressure vessels having a gross volume of more than 3 cubic feet but less than 10 ...
... fusible plug , or rupture member , pro- vided , however , that a fusible plug is permitted only on the high pressure side of the refrigerating system . Pressure vessels having a gross volume of more than 3 cubic feet but less than 10 ...
Page 233
... fusible plug and the part or parts of the system protected thereby , except when parallel relief devices are so ... Fusible plugs may be located above or below the liquid refrigerant level . Sec . 15.119 ( a ) General . Every refrigerant ...
... fusible plug and the part or parts of the system protected thereby , except when parallel relief devices are so ... Fusible plugs may be located above or below the liquid refrigerant level . Sec . 15.119 ( a ) General . Every refrigerant ...
Contents
Part Administrative | 9 |
CHAPTER | 15 |
Part IIDefinitions and Abbreviations | 21 |
Copyright | |
17 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit Addenda air ducts approved Asbestos-cement automatic boiler Building Official capacity Chapter chimney circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating comply compressor connected construction Continued cubic feet dampers designed diameter Dichlorodifluoromethane discharge duct system equipment evaporative cooler exceed fire fire-resistance rating flame fuel fuel-burning fusible plug gage galvanized gas vent Group 1 refrigerant horsepower incinerators inlet inspection installed iron pipe size joints less liquefied petroleum gas liquid listed located low pressure machinery room main burner metal Methyl Chloride minimum oil burners opening operating outlet permit plenum portion pounds per square pressure vessel protected psig pump refrigerant piping refrigerating system relief valve Required Required Required room or space sample Section shutoff valve side smoke detector specified square inch Standard steam steel supply tank Table temperature thickness tion Uniform Building Code vapor vent pipes ventilation venting system warm-air furnace