Uniform Building Code, Volume 2International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 27
Page 34
... vent pipe and vent fittings for conveying flue gases to the outside atmos- phere . Type B Gas Vent is a factory - made gas vent listed by a nationally recognized testing agency for venting listed or approved appliances equipped to burn ...
... vent pipe and vent fittings for conveying flue gases to the outside atmos- phere . Type B Gas Vent is a factory - made gas vent listed by a nationally recognized testing agency for venting listed or approved appliances equipped to burn ...
Page 71
... Vent Termination any forced air inlet located within 10 feet nor less than 4 feet ( Continued ) from any property line except a public way . ( g ) Outdoor Appliances with ... Vent Termination Vents for Wall Furnaces Requiring a Type Gas Vent.
... Vent Termination any forced air inlet located within 10 feet nor less than 4 feet ( Continued ) from any property line except a public way . ( g ) Outdoor Appliances with ... Vent Termination Vents for Wall Furnaces Requiring a Type Gas Vent.
Page 72
... gas vent used . Firestop - spacers furnished with the gas vent used shall be installed at each subsequent ceiling plate through which the gas vent passes . 7. A suitable metal guard shall be installed at the floor line of each floor ...
... gas vent used . Firestop - spacers furnished with the gas vent used shall be installed at each subsequent ceiling plate through which the gas vent passes . 7. A suitable metal guard shall be installed at the floor line of each floor ...
Contents
Part Administrative | 9 |
CHAPTER | 15 |
Part IIDefinitions and Abbreviations | 21 |
Copyright | |
17 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit Addenda air ducts approved Asbestos-cement automatic boiler Building Official capacity Chapter chimney circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating comply compressor connected construction Continued cubic feet dampers designed diameter Dichlorodifluoromethane discharge duct system equipment evaporative cooler exceed fire fire-resistance rating flame fuel fuel-burning fusible plug gage galvanized gas vent Group 1 refrigerant horsepower incinerators inlet inspection installed iron pipe size joints less liquefied petroleum gas liquid listed located low pressure machinery room main burner metal Methyl Chloride minimum oil burners opening operating outlet permit plenum portion pounds per square pressure vessel protected psig pump refrigerant piping refrigerating system relief valve Required Required Required room or space sample Section shutoff valve side smoke detector specified square inch Standard steam steel supply tank Table temperature thickness tion Uniform Building Code vapor vent pipes ventilation venting system warm-air furnace