... Inspection under this Code shall be inspected by the Building Official . No portion of any equipment intended to be concealed by any permanent portion of the building shall be concealed until inspected and approved . When the ...
... Inspection under this Code shall be inspected by the Building Official . No portion of any equipment intended to be concealed by any permanent portion of the building shall be concealed until inspected and approved . When the ...
Page 142
International Conference of Building Officials. Inspections and Tests ( Continued ) Operating Permit Maintenance Inspection ready for inspection and test . It also shall be the duty of the owner or his authorized representative to post ...
International Conference of Building Officials. Inspections and Tests ( Continued ) Operating Permit Maintenance Inspection ready for inspection and test . It also shall be the duty of the owner or his authorized representative to post ...
Page 154
... inspection . This inspection shall be made after all gas piping authorized by the permit has been installed , and before any such piping has been covered or concealed , or any fixture or appliance has been attached there- to . This ...
... inspection . This inspection shall be made after all gas piping authorized by the permit has been installed , and before any such piping has been covered or concealed , or any fixture or appliance has been attached there- to . This ...
Contents
Part Administrative | 9 |
CHAPTER | 15 |
Part IIDefinitions and Abbreviations | 21 |
Copyright | |
17 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit Addenda air ducts approved Asbestos-cement automatic boiler Building Official capacity Chapter chimney circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating comply compressor connected construction Continued cubic feet dampers designed diameter Dichlorodifluoromethane discharge duct system equipment evaporative cooler exceed fire fire-resistance rating flame fuel fuel-burning fusible plug gage galvanized gas vent Group 1 refrigerant horsepower incinerators inlet inspection installed iron pipe size joints less liquefied petroleum gas liquid listed located low pressure machinery room main burner metal Methyl Chloride minimum oil burners opening operating outlet permit plenum portion pounds per square pressure vessel protected psig pump refrigerant piping refrigerating system relief valve Required Required Required room or space sample Section shutoff valve side smoke detector specified square inch Standard steam steel supply tank Table temperature thickness tion Uniform Building Code vapor vent pipes ventilation venting system warm-air furnace