Page 145
... iron pipe size ( I.P.S. Pipe ) shall be standard taper pipe threads . All burrs shall be re- moved . Pipe ends shall be reamed or filed out to full size of bore , and all chips shall be removed . ( 2 ) Solder joints . Surfaces to be ...
... iron pipe size ( I.P.S. Pipe ) shall be standard taper pipe threads . All burrs shall be re- moved . Pipe ends shall be reamed or filed out to full size of bore , and all chips shall be removed . ( 2 ) Solder joints . Surfaces to be ...
Page 193
... iron , steel or brass pipe , or brass or copper tubing . Aluminum tub- ing shall not be used between the fuel oil ... Size . Piping used in the installation of oil burners and appliances other than conversion range oil burners shall be not ...
... iron , steel or brass pipe , or brass or copper tubing . Aluminum tub- ing shall not be used between the fuel oil ... Size . Piping used in the installation of oil burners and appliances other than conversion range oil burners shall be not ...
Page 242
International Conference of Building Officials. Scope Material Requirements Size Dimensions and Weights Pipe Threads Schedule Wall Pipe UNIFORM MECHANICAL CODE STANDARD NO . 15-2 WROUGHT STEEL AND WROUGHT IRON PIPE Based on Standard B36 ...
International Conference of Building Officials. Scope Material Requirements Size Dimensions and Weights Pipe Threads Schedule Wall Pipe UNIFORM MECHANICAL CODE STANDARD NO . 15-2 WROUGHT STEEL AND WROUGHT IRON PIPE Based on Standard B36 ...
Contents
Part Administrative | 9 |
CHAPTER | 15 |
Part IIDefinitions and Abbreviations | 21 |
Copyright | |
17 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit Addenda air ducts approved Asbestos-cement automatic boiler Building Official capacity Chapter chimney circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating comply compressor connected construction Continued cubic feet dampers designed diameter Dichlorodifluoromethane discharge duct system equipment evaporative cooler exceed fire fire-resistance rating flame fuel fuel-burning fusible plug gage galvanized gas vent Group 1 refrigerant horsepower incinerators inlet inspection installed iron pipe size joints less liquefied petroleum gas liquid listed located low pressure machinery room main burner metal Methyl Chloride minimum oil burners opening operating outlet permit plenum portion pounds per square pressure vessel protected psig pump refrigerant piping refrigerating system relief valve Required Required Required room or space sample Section shutoff valve side smoke detector specified square inch Standard steam steel supply tank Table temperature thickness tion Uniform Building Code vapor vent pipes ventilation venting system warm-air furnace