... listed by a nationally recognized testing agency for venting listed or approved gas - fired vented wall furnaces . Type L is a venting system consisting of listed vent piping and fittings for use with oil - burning appliances listed for ...
... listed by a nationally recognized testing agency for venting listed or approved gas - fired vented wall furnaces . Type L is a venting system consisting of listed vent piping and fittings for use with oil - burning appliances listed for ...
Page 46
... Listed Gas Burners and with Draft Hoods 92 Oil Appliances Listed as Suitable for Use with Type L Venting Systems ( but only when con- nected to chimneys ) Listed Gas Appliances with Draft Hoods COMMERCIAL - INDUSTRIAL TYPE APPLIANCES ...
... Listed Gas Burners and with Draft Hoods 92 Oil Appliances Listed as Suitable for Use with Type L Venting Systems ( but only when con- nected to chimneys ) Listed Gas Appliances with Draft Hoods COMMERCIAL - INDUSTRIAL TYPE APPLIANCES ...
Page 66
... Listed for Reduced Clearances . Unit heaters listed for reduced clearances may be installed at the clearances indicated on the required manufacturer's label . ( d ) Unit Heaters Listed for Greater Clearances . Unit heat- ers listed for ...
... Listed for Reduced Clearances . Unit heaters listed for reduced clearances may be installed at the clearances indicated on the required manufacturer's label . ( d ) Unit Heaters Listed for Greater Clearances . Unit heat- ers listed for ...
Contents
Part Administrative | 9 |
CHAPTER | 15 |
Part IIDefinitions and Abbreviations | 21 |
Copyright | |
17 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit Addenda air ducts approved Asbestos-cement automatic boiler Building Official capacity Chapter chimney circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating comply compressor connected construction Continued cubic feet dampers designed diameter Dichlorodifluoromethane discharge duct system equipment evaporative cooler exceed fire fire-resistance rating flame fuel fuel-burning fusible plug gage galvanized gas vent Group 1 refrigerant horsepower incinerators inlet inspection installed iron pipe size joints less liquefied petroleum gas liquid listed located low pressure machinery room main burner metal Methyl Chloride minimum oil burners opening operating outlet permit plenum portion pounds per square pressure vessel protected psig pump refrigerant piping refrigerating system relief valve Required Required Required room or space sample Section shutoff valve side smoke detector specified square inch Standard steam steel supply tank Table temperature thickness tion Uniform Building Code vapor vent pipes ventilation venting system warm-air furnace