Page 136
... burner assembly . CONTINUOUS PILOT is a pilot that burns without turn down throughout the entire period that the boiler is in service , whether or not the main burner is firing . HOT WATER SUPPLY BOILER is a boiler having volume ...
... burner assembly . CONTINUOUS PILOT is a pilot that burns without turn down throughout the entire period that the boiler is in service , whether or not the main burner is firing . HOT WATER SUPPLY BOILER is a boiler having volume ...
Page 139
... main burner of a gas - fired boiler . The take - off point for the gas supply to the pilot shall be up - stream of the gas shutoff valve of the main burner and shall be valved separately . A union or other ap- proved means of disconnect ...
... main burner of a gas - fired boiler . The take - off point for the gas supply to the pilot shall be up - stream of the gas shutoff valve of the main burner and shall be valved separately . A union or other ap- proved means of disconnect ...
Page 181
... burner where fuel to the main burner is normally turned on and ignited automatically . BURNER , MANUALLY LIGHTED , is a burner where fuel to the main burner is turned on only by hand and ignited under supervision . Sec . 5.105 ...
... burner where fuel to the main burner is normally turned on and ignited automatically . BURNER , MANUALLY LIGHTED , is a burner where fuel to the main burner is turned on only by hand and ignited under supervision . Sec . 5.105 ...
Contents
Part Administrative | 9 |
CHAPTER | 15 |
Part IIDefinitions and Abbreviations | 21 |
Copyright | |
17 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit Addenda air ducts approved Asbestos-cement automatic boiler Building Official capacity Chapter chimney circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating comply compressor connected construction Continued cubic feet dampers designed diameter Dichlorodifluoromethane discharge duct system equipment evaporative cooler exceed fire fire-resistance rating flame fuel fuel-burning fusible plug gage galvanized gas vent Group 1 refrigerant horsepower incinerators inlet inspection installed iron pipe size joints less liquefied petroleum gas liquid listed located low pressure machinery room main burner metal Methyl Chloride minimum oil burners opening operating outlet permit plenum portion pounds per square pressure vessel protected psig pump refrigerant piping refrigerating system relief valve Required Required Required room or space sample Section shutoff valve side smoke detector specified square inch Standard steam steel supply tank Table temperature thickness tion Uniform Building Code vapor vent pipes ventilation venting system warm-air furnace