Uniform Building Code, Volume 2International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 22
Page 22
International Conference of Building Officials. A ( Continued ) B APPROVED AGENCY is an established and recognized agency ... pounds per square inch or hot water at temperatures in excess of 250 ° F . , or at pres- sures in excess of 160 ...
International Conference of Building Officials. A ( Continued ) B APPROVED AGENCY is an established and recognized agency ... pounds per square inch or hot water at temperatures in excess of 250 ° F . , or at pres- sures in excess of 160 ...
Page 136
... of the main burner . LOW PRESSURE HOT WATER HEATING BOILER is a boiler in which water is heated for the purpose of supplying heat at pressures not exceeding 160 pounds per square inch and temperatures not exceeding 250 ° F . LOW ...
... of the main burner . LOW PRESSURE HOT WATER HEATING BOILER is a boiler in which water is heated for the purpose of supplying heat at pressures not exceeding 160 pounds per square inch and temperatures not exceeding 250 ° F . LOW ...
Page 137
... pounds per square inch or to a temperature exceeding 250 ° F . POWER STEAM BOILER is a boiler in which steam or other vapor is generated at pressures exceeding 15 pounds per square inch . PRESSURE VESSEL ( Unfired ) is a closed ...
... pounds per square inch or to a temperature exceeding 250 ° F . POWER STEAM BOILER is a boiler in which steam or other vapor is generated at pressures exceeding 15 pounds per square inch . PRESSURE VESSEL ( Unfired ) is a closed ...
Contents
Part Administrative | 9 |
CHAPTER | 15 |
Part IIDefinitions and Abbreviations | 21 |
Copyright | |
17 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit Addenda air ducts approved Asbestos-cement automatic boiler Building Official capacity Chapter chimney circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating comply compressor connected construction Continued cubic feet dampers designed diameter Dichlorodifluoromethane discharge duct system equipment evaporative cooler exceed fire fire-resistance rating flame fuel fuel-burning fusible plug gage galvanized gas vent Group 1 refrigerant horsepower incinerators inlet inspection installed iron pipe size joints less liquefied petroleum gas liquid listed located low pressure machinery room main burner metal Methyl Chloride minimum oil burners opening operating outlet permit plenum portion pounds per square pressure vessel protected psig pump refrigerant piping refrigerating system relief valve Required Required Required room or space sample Section shutoff valve side smoke detector specified square inch Standard steam steel supply tank Table temperature thickness tion Uniform Building Code vapor vent pipes ventilation venting system warm-air furnace