Uniform Building Code, Volume 2International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 39
Page 114
... system shall be installed in any location where it would be subject to damage from an external source . No portion of any direct refrigerating system shall be lo- cated in ... Refrigerating Equipment Group 1 Refrigerants Group 2 Refrigerants.
... system shall be installed in any location where it would be subject to damage from an external source . No portion of any direct refrigerating system shall be lo- cated in ... Refrigerating Equipment Group 1 Refrigerants Group 2 Refrigerants.
Page 126
... this Section shall be conducted by the owner or contractor in the presence of the Building Offi- cial . CHAPTER 16 - STORAGE OF REFRIGERANTS Sec . 1601. All 126 SECTION 1520 UNIFORM MECHANICAL CODE Testing of Refrigerating Equipment.
... this Section shall be conducted by the owner or contractor in the presence of the Building Offi- cial . CHAPTER 16 - STORAGE OF REFRIGERANTS Sec . 1601. All 126 SECTION 1520 UNIFORM MECHANICAL CODE Testing of Refrigerating Equipment.
Page 223
... refrigerant - containing recep- tacle of a refrigerating system , other than evaporators , each separate section of which does not exceed one - half cubic foot of refrigerant - containing volume , expansion coils , compressors ...
... refrigerant - containing recep- tacle of a refrigerating system , other than evaporators , each separate section of which does not exceed one - half cubic foot of refrigerant - containing volume , expansion coils , compressors ...
Contents
Part Administrative | 9 |
CHAPTER | 15 |
Part IIDefinitions and Abbreviations | 21 |
Copyright | |
17 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit Addenda air ducts approved Asbestos-cement automatic boiler Building Official capacity Chapter chimney circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating comply compressor connected construction Continued cubic feet dampers designed diameter Dichlorodifluoromethane discharge duct system equipment evaporative cooler exceed fire fire-resistance rating flame fuel fuel-burning fusible plug gage galvanized gas vent Group 1 refrigerant horsepower incinerators inlet inspection installed iron pipe size joints less liquefied petroleum gas liquid listed located low pressure machinery room main burner metal Methyl Chloride minimum oil burners opening operating outlet permit plenum portion pounds per square pressure vessel protected psig pump refrigerant piping refrigerating system relief valve Required Required Required room or space sample Section shutoff valve side smoke detector specified square inch Standard steam steel supply tank Table temperature thickness tion Uniform Building Code vapor vent pipes ventilation venting system warm-air furnace