Uniform Building Code, Volume 2International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 21
Page 54
... warm - air furnace and comfort heating systems . In addition to the gen- eral requirements of Chapter 5 , every warm - air furnace and comfort heating system shall be installed to conform to the requirements of this Chapter . Sec . 702 ...
... warm - air furnace and comfort heating systems . In addition to the gen- eral requirements of Chapter 5 , every warm - air furnace and comfort heating system shall be installed to conform to the requirements of this Chapter . Sec . 702 ...
Page 57
... warm - air furnace shall be not less than 7 square inches for each 1000 B.t.u. approved hourly rating or as indicated by the conditions of listing of the furnace ... Air Supply ( Continued ) Conditioned Air Supply to 57 1970 EDITION SECTION ...
... warm - air furnace shall be not less than 7 square inches for each 1000 B.t.u. approved hourly rating or as indicated by the conditions of listing of the furnace ... Air Supply ( Continued ) Conditioned Air Supply to 57 1970 EDITION SECTION ...
Page 59
... furnace . Supply ( Continued ) For the purpose of this Section a volume damper , grille , or register installed for the purpose of controlling the conditioned air flow shall not ... Furnaces 709 Warm-Air Furnaces Located in Underfloor Spaces.
... furnace . Supply ( Continued ) For the purpose of this Section a volume damper , grille , or register installed for the purpose of controlling the conditioned air flow shall not ... Furnaces 709 Warm-Air Furnaces Located in Underfloor Spaces.
Contents
Part Administrative | 9 |
CHAPTER | 15 |
Part IIDefinitions and Abbreviations | 21 |
Copyright | |
17 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit Addenda air ducts approved Asbestos-cement automatic boiler Building Official capacity Chapter chimney circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating comply compressor connected construction Continued cubic feet dampers designed diameter Dichlorodifluoromethane discharge duct system equipment evaporative cooler exceed fire fire-resistance rating flame fuel fuel-burning fusible plug gage galvanized gas vent Group 1 refrigerant horsepower incinerators inlet inspection installed iron pipe size joints less liquefied petroleum gas liquid listed located low pressure machinery room main burner metal Methyl Chloride minimum oil burners opening operating outlet permit plenum portion pounds per square pressure vessel protected psig pump refrigerant piping refrigerating system relief valve Required Required Required room or space sample Section shutoff valve side smoke detector specified square inch Standard steam steel supply tank Table temperature thickness tion Uniform Building Code vapor vent pipes ventilation venting system warm-air furnace