Uniform Building Code |
From inside the book
Results 1-3 of 82
Page 27
... OCCUPANCY AND GENERAL REQUIREMENTS FOR ALL OCCUPANCIES Occupancy Classified Sec . 501. Every building , whether existing or hereafter erected , shall be classified by the building official , according to its use or the character of its ...
... OCCUPANCY AND GENERAL REQUIREMENTS FOR ALL OCCUPANCIES Occupancy Classified Sec . 501. Every building , whether existing or hereafter erected , shall be classified by the building official , according to its use or the character of its ...
Page 28
... occupancy separation need not be provided between a Group R , Division 3 Occupancy and a carport having no enclosed uses above , provided the carport is entirely open on two or more sides . When a building houses more than one occupancy ...
... occupancy separation need not be provided between a Group R , Division 3 Occupancy and a carport having no enclosed uses above , provided the carport is entirely open on two or more sides . When a building houses more than one occupancy ...
Page 29
... occupancy separa- tion " shall be protected by vertical enclosures extending above and below such openings . The walls of such vertical enclosures shall be of not less than two - hour fire - resistive construction and all openings ...
... occupancy separa- tion " shall be protected by vertical enclosures extending above and below such openings . The walls of such vertical enclosures shall be of not less than two - hour fire - resistive construction and all openings ...
Contents
Organization and Enforcement | 4 |
Part IIDefinitions and Abbreviations | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
103 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section Allowable Unit Stresses applied approved atrium axial load bars beam bolts building official building or structure column comply compression members concrete conform dead load deflection diameter diaphragms Division 1 Occupancies exceed exit exterior walls extreme fiber factor Fire Code floor area Formula framing girders grade Group H grout height horizontal shear inspection installed joints joists laminations lateral forces length less live load located lumber materials maximum minimum modulus of elasticity nails noncombustible occupancy separation openings panel Parallel to Grain particleboard partitions percent permitted perpendicular plywood portion pounds per square prestressing protected psi psi psi ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel storage strength Stud Table tensile tensile stress tension thickness U.B.C. Standard vertical welds width wood yield strength