Uniform Building Code |
From inside the book
Results 1-3 of 80
Page xxi
International Conference of Building Officials. BUILDING CODE The following procedure may be helpful in using the Uniform Building Code : 1. Classify the building : A. OCCUPANCY GROUP : Determine the occupancy group which the use of the ...
International Conference of Building Officials. BUILDING CODE The following procedure may be helpful in using the Uniform Building Code : 1. Classify the building : A. OCCUPANCY GROUP : Determine the occupancy group which the use of the ...
Page 2
... building so altered , which involves a change in use or occupancy , shall not exceed the height , number of stories and area permitted for new buildings ... building or structure has been designated by official 2 104 UNIFORM BUILDING CODE.
... building so altered , which involves a change in use or occupancy , shall not exceed the height , number of stories and area permitted for new buildings ... building or structure has been designated by official 2 104 UNIFORM BUILDING CODE.
Page 30
... building including the court is within the allowable area and ( 3 ) the building is not classified as a Group I Occupancy . When a new building is to be erected on the same property as an existing building , the location of the assumed ...
... building including the court is within the allowable area and ( 3 ) the building is not classified as a Group I Occupancy . When a new building is to be erected on the same property as an existing building , the location of the assumed ...
Contents
Organization and Enforcement | 4 |
Part IIDefinitions and Abbreviations | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
103 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section Allowable Unit Stresses applied approved atrium axial load bars beam bolts building official building or structure column comply compression members concrete conform dead load deflection diameter diaphragms Division 1 Occupancies exceed exit exterior walls extreme fiber factor Fire Code floor area Formula framing girders grade Group H grout height horizontal shear inspection installed joints joists laminations lateral forces length less live load located lumber materials maximum minimum modulus of elasticity nails noncombustible occupancy separation openings panel Parallel to Grain particleboard partitions percent permitted perpendicular plywood portion pounds per square prestressing protected psi psi psi ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel storage strength Stud Table tensile tensile stress tension thickness U.B.C. Standard vertical welds width wood yield strength