Uniform Building Code |
From inside the book
Results 1-3 of 75
Page 83
... covered by a minimum of 1 - inch thickness of masonry or concrete in a wall , floor or roof system . 2. Attics and crawl spaces . Within an attic or crawl space where entry is made only for service of utilities , foam plastics shall be ...
... covered by a minimum of 1 - inch thickness of masonry or concrete in a wall , floor or roof system . 2. Attics and crawl spaces . Within an attic or crawl space where entry is made only for service of utilities , foam plastics shall be ...
Page 733
... covered mall buildings having not more than three levels . ( b ) Scope . The provisions of this chapter shall apply to buildings or structures defined herein as covered mall buildings . This chapter does not apply to terminals for ...
... covered mall buildings having not more than three levels . ( b ) Scope . The provisions of this chapter shall apply to buildings or structures defined herein as covered mall buildings . This chapter does not apply to terminals for ...
Page 736
... Covered mall buildings exceeding 50,000 square feet in total floor area shall be provided with a public address system accessible for use by the fire department . Covered mall buildings of 50,000 square feet or less in total floor area ...
... Covered mall buildings exceeding 50,000 square feet in total floor area shall be provided with a public address system accessible for use by the fire department . Covered mall buildings of 50,000 square feet or less in total floor area ...
Contents
Organization and Enforcement | 4 |
Part IIDefinitions and Abbreviations | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
103 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section Allowable Unit Stresses applied approved atrium axial load bars beam bolts building official building or structure column comply compression members concrete conform dead load deflection diameter diaphragms Division 1 Occupancies exceed exit exterior walls extreme fiber factor Fire Code floor area Formula framing girders grade Group H grout height horizontal shear inspection installed joints joists laminations lateral forces length less live load located lumber materials maximum minimum modulus of elasticity nails noncombustible occupancy separation openings panel Parallel to Grain particleboard partitions percent permitted perpendicular plywood portion pounds per square prestressing protected psi psi psi ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel storage strength Stud Table tensile tensile stress tension thickness U.B.C. Standard vertical welds width wood yield strength