Page 31
B. Where roof - ceiling framing elements are perpendicular to the wall , the entire span of such framing and elements supporting such framing shall be of not less than one - hour fire - resistive construction .
B. Where roof - ceiling framing elements are perpendicular to the wall , the entire span of such framing and elements supporting such framing shall be of not less than one - hour fire - resistive construction .
Page 281
SSD is dense select structural , structural joists and planks , or structural light framing grade ( dense ) . SS is select structural , structural joists and planks , or structural light framing grade ( medium grain for Douglas fir ...
SSD is dense select structural , structural joists and planks , or structural light framing grade ( dense ) . SS is select structural , structural joists and planks , or structural light framing grade ( medium grain for Douglas fir ...
Page 300
MINIMUM MINIMUM NAIL NOMINAL PANEL PENETRATION THICKNESS IN FRAMING ( In . ) ( In . ) 5/16 PANELS APPLIED OVER 12 " GYPSUM SHEATHING Nail Size Nail Spacing at Panel Edges ( In . ) ( Common or galvanized box ) 180 270 350 450 PANEL GRADE ...
MINIMUM MINIMUM NAIL NOMINAL PANEL PENETRATION THICKNESS IN FRAMING ( In . ) ( In . ) 5/16 PANELS APPLIED OVER 12 " GYPSUM SHEATHING Nail Size Nail Spacing at Panel Edges ( In . ) ( Common or galvanized box ) 180 270 350 450 PANEL GRADE ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Definitions and Abbreviations | 17 |
Fireresistive Substitution | 33 |
Pedestrian Walkways | 34 |
Copyright | |
119 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved axial bars beam bearing bending building official Chapter column combination comply compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined direction distance Division edge effective elasticity elements equipment exceed EXCEPTION exit exterior walls face factor feet fiber fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal hour inches increased inspection installed joints lateral least length less limited live load located masonry materials maximum modulus nails Occupancies one-hour openings panel parallel percent permitted placed portion protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab space span specified square steel storage story strength stress Structural Stud surface Table tension thickness Type U.B.C. Standard unit values vertical walls welds wide width wood