Uniform Building Code |
From inside the book
Results 1-3 of 83
Page 257
9Stress - rated boards of nominal 1 - inch , 1 / 4 - inch and 1 / 2 - inch thickness , 2 inches and wider , are permitted the recommended design values shown for Select Structural , No. 1 , No. 2 , No.
9Stress - rated boards of nominal 1 - inch , 1 / 4 - inch and 1 / 2 - inch thickness , 2 inches and wider , are permitted the recommended design values shown for Select Structural , No. 1 , No. 2 , No.
Page 529
The design f ' shall not exceed 5000 pounds per square inch and the ratio of metal yield strength shall be not less than 6 . 4. The pile diameter is not greater than 16 inches . ( d ) Precast Concrete Piles . 1. Material .
The design f ' shall not exceed 5000 pounds per square inch and the ratio of metal yield strength shall be not less than 6 . 4. The pile diameter is not greater than 16 inches . ( d ) Precast Concrete Piles . 1. Material .
Page 546
An 18 - inch - wide strip of the same asbestos felt shall be shingled in between each course of shakes in such manner ... shall be overlaid with a layer of approved asbestos felt lapped 2 inches on the horizontal and vertical joints .
An 18 - inch - wide strip of the same asbestos felt shall be shingled in between each course of shakes in such manner ... shall be overlaid with a layer of approved asbestos felt lapped 2 inches on the horizontal and vertical joints .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Definitions and Abbreviations | 17 |
Fireresistive Substitution | 33 |
Pedestrian Walkways | 34 |
Copyright | |
119 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved axial bars beam bearing bending building official Chapter column combination comply compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined direction distance Division edge effective elasticity elements equipment exceed EXCEPTION exit exterior walls face factor feet fiber fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal hour inches increased inspection installed joints lateral least length less limited live load located masonry materials maximum modulus nails Occupancies one-hour openings panel parallel percent permitted placed portion protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab space span specified square steel storage story strength stress Structural Stud surface Table tension thickness Type U.B.C. Standard unit values vertical walls welds wide width wood